Machine Overzicht

Generator events en service beheer USB: 6D21CD9278 ×
Records
124
van 353,752
Machines
1
Starts
0
Warnings
124
24 resultaten · pagina 5 van 5
Dubbelklik service uren om te bewerken
ID Machine Gebeurtenis Tijd Uren Service Status USB ID
300405 OC006 Gen Over Current Warning 25-07-2025 21:30:07 14,601 500 OVER BEURT URGENT! 6D21CD9278
300404 OC006 Gen Over Current Warning 25-07-2025 21:11:27 14,600 500 OVER BEURT URGENT! 6D21CD9278
300402 OC006 Gen Over Current Warning 25-07-2025 20:54:31 14,600 500 OVER BEURT URGENT! 6D21CD9278
300399 OC006 Gen Over Current Warning 25-07-2025 20:14:39 14,599 500 OVER BEURT URGENT! 6D21CD9278
300397 OC006 Gen Over Current Warning 25-07-2025 19:57:42 14,599 500 OVER BEURT URGENT! 6D21CD9278
300396 OC006 Gen Over Current Warning 25-07-2025 19:40:07 14,599 500 OVER BEURT URGENT! 6D21CD9278
300395 OC006 Gen Over Current Warning 25-07-2025 19:21:03 14,599 500 OVER BEURT URGENT! 6D21CD9278
300392 OC006 Gen Over Current Warning 25-07-2025 18:58:19 14,598 500 OVER BEURT URGENT! 6D21CD9278
298973 OC006 Emergency Stop Shutdown 18-07-2025 08:39:56 14,597 500 OVER BEURT URGENT! 6D21CD9278
297577 OC006 Shutdown 15-07-2025 04:44:22 14,571 500 OVER BEURT URGENT! 6D21CD9278
297576 OC006 Emergency Stop Shutdown 15-07-2025 04:43:04 14,571 500 OVER BEURT URGENT! 6D21CD9278
295891 OC006 Shutdown 08-07-2025 10:20:23 14,558 500 OVER BEURT URGENT! 6D21CD9278
285622 OC006 Shutdown 29-01-2025 05:43:51 14,129 500 OVER BEURT URGENT! 6D21CD9278
285203 OC006 Shutdown 28-01-2025 06:10:38 14,120 500 OVER BEURT URGENT! 6D21CD9278
280134 OC006 Shutdown 07-01-2025 13:12:28 14,060 500 OVER BEURT URGENT! 6D21CD9278
280133 OC006 Shutdown 07-01-2025 13:11:22 14,060 500 OVER BEURT URGENT! 6D21CD9278
280132 OC006 Shutdown 07-01-2025 13:10:19 14,060 500 OVER BEURT URGENT! 6D21CD9278
280131 OC006 Shutdown 07-01-2025 13:05:48 14,060 500 OVER BEURT URGENT! 6D21CD9278
280129 OC006 Warning 07-01-2025 13:01:45 14,060 500 OVER BEURT URGENT! 6D21CD9278
280130 OC006 Shutdown 07-01-2025 13:01:32 14,060 500 OVER BEURT URGENT! 6D21CD9278
263580 OC006 Battery Under Voltage Warning 09-11-2024 00:22:12 14,060 500 OVER BEURT URGENT! 6D21CD9278
170307 OC006 Oil Pressure Low Switch Shutdown 07-10-2024 08:04:30 14,046 500 OVER BEURT URGENT! 6D21CD9278
6176 OC006 Shutdown 26-08-2024 05:04:21 13,884 500 OVER BEURT URGENT! 6D21CD9278
5082 OC006 Emergency Stop Shutdown 19-08-2024 13:03:24 13,857 500 OVER BEURT URGENT! 6D21CD9278
101–124 van 124